What this symptom may mean
In a gas furnace, the blower and burners are separate, and the blower keeps going for a while after the burners stop. If the burners never light, or light and quickly go out, the blower just circulates cool house air.
A brief puff of cool air at the start of a cycle is normal while the heat exchanger warms. Cold air lasting more than a few minutes is not.
Possible causes
Fan set to ON
The blower runs nonstop and pushes room-temperature air between cycles, which feels cold.
Overheated limit switch
A dirty filter causes overheating, so the burners shut off while the fan keeps running.
Ignition failure
When the igniter or flame sensor fails, the burners will not stay lit.
Duct leaks in unheated space
Disconnected ducts in a crawlspace or attic let warm air escape and pull cold air in.
Condensate problem on high-efficiency units
Some high-efficiency furnaces stop the burners when their condensate drain backs up.
Safe checks you can make
- Set the thermostat fan to AUTO, then confirm the mode is HEAT and the setpoint is above room temperature.
- Replace a dirty air filter and give the furnace a few minutes to restart its sequence.
- On high-efficiency furnaces, look at the plastic condensate line for kinks or standing water without disconnecting it.
- Feel the registers after ten minutes. Warm air in some rooms and cold in others points to ducts rather than the furnace.
What not to do
- Don't ignore a rotten-egg odor. Get everyone outside first and call the gas utility or 911 from there.
- Don't open the burner compartment or try to relight anything by hand.
- Don't keep cycling the power to force repeated ignition attempts.
- Don't crawl into tight attic or crawlspace areas to reconnect ductwork yourself.
When professional evaluation may be appropriate
If the fan setting and filter are correct and the air stays cold, the burners are not lighting or not staying lit. That points to ignition, gas valve, pressure switch or control problems that need a technician.
Call to be connected with a local provider for furnace repair. Cold air in only certain rooms may call for ductwork repair instead.
- Cold air continues with the fan on AUTO and a new filter
- The furnace clicks repeatedly without lighting
- Any rotten-egg smell near the equipment (leave, then call)
What an HVAC provider may inspect
- Burner operation and ignition parts
- Limit switch and airflow across the heat exchanger
- Gas valve and supply pressure
- Duct connections in attics and crawlspaces
Keeping it from happening again
Keep the fan on AUTO during heating season and change the filter before winter. Older homes in the region with crawlspace ducts benefit from an occasional duct inspection, since a disconnected run often goes unnoticed until the first cold snap.