Heat pump problems

Heat Pump Not Heating the House

Heat pumps are common in central Alabama, and some of what looks like trouble is normal operation.

Quick answer

A heat pump that seems not to heat may be in a normal defrost cycle, set to the wrong thermostat mode, or held back by a clogged filter or an iced outdoor coil. Low refrigerant, a stuck reversing valve, or failed backup heat strips are other common causes. Check the thermostat and filter first, and call if warm air does not return.

Heat pump outdoor unit on a pad beside a home with flowering shrubs

What this symptom may mean

A heat pump moves heat from outdoor air into the house, even on cold days. Its air feels warm but not as hot as a gas furnace's, so it can seem lukewarm to the hand. That is normal if the rooms still reach the setpoint.

In cold, damp weather, frost builds on the outdoor coil, so the system runs a defrost cycle, briefly reversing to warm the coil. Expect a whoosh, some steam and a few minutes of cooler air before heating resumes.

Auxiliary heat is a backup, usually electric heat strips, that switches on by itself when the heat pump needs help. Emergency heat is a setting you choose that runs only that backup, meant for when the outdoor unit fails.

Possible causes

  1. Normal defrost cycle

    Steam and a short pause in heat are expected, especially on cold, humid mornings.

  2. Thermostat setup

    The thermostat may be in COOL, or emergency heat may have been switched by accident.

  3. Heavy ice on the outdoor coil

    If defrost fails, ice can encase the coil and block heat transfer.

  4. Auxiliary heat failure

    When backup heat strips fail, the house may fall behind on the coldest days.

Safe checks you can make

  • Confirm the thermostat is on HEAT with a setpoint above room temperature, and check batteries.
  • Replace the air filter, since heat pumps rely on steady airflow.
  • Look at the outdoor unit. Light frost that clears periodically is normal; solid ice for hours is not.
  • Clear leaves and debris from around the outdoor unit, and make sure gutters are not dripping onto it.
  • Check the indoor and outdoor breakers, resetting a tripped one once at most.

What not to do

  • Don't chip ice or pour hot water on the outdoor coil. It can damage the fins and tubing.
  • Don't leave the system on emergency heat for days unless a provider recommends it.
  • Don't open the outdoor unit or touch any electrical parts.
  • Don't keep resetting a breaker that trips again.

When professional evaluation may be appropriate

Call if the outdoor unit stays encased in ice, auxiliary heat runs almost constantly, or the house cannot reach the setpoint on mild days. Defrost, refrigerant or valve trouble is likely.

Call to be connected with an independent provider for heat pump repair in the Montgomery, AL area. Ductless systems have their own guidance on the mini-split page.

  • Ice covers the outdoor coil for hours
  • Auxiliary heat shows as running nearly all the time
  • Cold air from the vents outside of defrost

What an HVAC provider may inspect

  • Defrost control board and sensors
  • Reversing valve operation
  • Refrigerant charge and leak points
  • Auxiliary heat strips and sequencers

Keeping it from happening again

Keep the outdoor unit clear of leaves and gutter runoff and change filters on schedule. Heat pumps here run most of the year, so spring and fall checkups help them through hard freezes and long summers alike.

Call now

Still not sure what's wrong?

Call and describe what you're seeing. You'll be connected with an independent HVAC provider serving homes in the Montgomery, AL area.

Call Now

The line is for homeowners who need HVAC or AC repair, replacement or installation. It can't help with billing or service already scheduled with a company.

Questions homeowners ask

Heat Pump Not Heating: questions homeowners ask

Call Now

Why is steam coming off my heat pump in winter?

Steam usually signals the defrost cycle. The heat pump reverses briefly to warm the outdoor coil and melt frost, and the meltwater gives off vapor in cold air. It often lasts a few minutes before normal heating resumes. Ice or steam lasting hours is worth a call.

What does auxiliary heat mean on my thermostat?

Auxiliary heat is the backup heat source, often electric strips, that comes on automatically when the heat pump needs help, such as on very cold days or during defrost. Seeing it now and then is normal. Seeing it nearly constantly suggests the heat pump is not keeping up.

When should I use emergency heat?

Emergency heat runs only the backup heat source and leaves the heat pump off. It is meant for times when the outdoor unit is badly iced, damaged or not running. Use it temporarily while you call for service, since it draws a lot of electricity.

Why does heat pump air feel lukewarm?

Heat pumps deliver warm air at a lower temperature than a gas furnace, so it can feel only mildly warm on your hand. That is normal. The real test is whether the room temperature reaches the setpoint and holds there over time.

Can my heat pump keep up during a hard freeze?

Heat pumps work less efficiently as outdoor temperatures fall, which is why many include auxiliary heat. During the occasional hard freeze in central Alabama, backup heat may run more often. If the house still falls behind, a provider can check both systems.

Why is my heat pump blowing cold air?

Cool air for a few minutes during defrost is normal. Cold air outside of defrost may mean the thermostat is set to COOL, the reversing valve is stuck, or the system is low on refrigerant. Check the settings, then call if it continues.